Предлагаем вам купить "6AG2137-6AA01-4BA0
по выгодной цене оптом или в розницу. Артикул данного товара - "6AG2137-6AA01-4BA0", бренд – "Siemens". Мы осуществляем доставку по Москве и всей России; гарантируем доставку товара в срок. После оформления заказа, наша команда свяжется с Вами для подтверждения заказа и уточнения деталей доставки. Если у Вас возникли вопросы или требуется помощь в выборе товара, Вы можете связаться с нашим отделом продаж.
6AG2137-6AA01-4BA0, 6AG2137 6AA01 4BA0
3964 (R) |
Bits per character |
7 or 8 |
Number of stop bits |
1 or 2 bit |
Parity |
None, even, odd, always 1, always 0, any |
Telegram length, max |
2kbyte; performance mode: receive data max. 24 byte and send data max. 30 byte |
Address space per module |
Inputs |
8byte; performance mode: 32 byte |
Address space per module |
Outputs |
0byte; performance mode: 32 byte |
Alarms |
Hardware interrupt |
No |
Alarms |
Diagnostic alarm |
Yes |
Altitude during operation relating to sea level |
Ambient air temperature-barometric pressure-altitude |
Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) |
Altitude during operation relating to sea level |
Installation altitude above sea level, max |
2000m |
Ambient temperature during operation |
horizontal installation, max |
70C; = Tmax; +85 C for 10 min (OT4, ST1/ST2 acc. to EN 50155) |
Ambient temperature during operation |
vertical installation, max |
50C; = Tmax |
Ambient temperature during operation |
horizontal installation, min |
-40C; = Tmin (incl. condensation/frost) |
vertical installation, min |
-40C; = Tmin |
Conformal coating |
Electronic equipment on rolling stock acc. to EN 50155 |
Yes; Class PC2 protective coating acc. to EN 50155:2017 |
Conformal coating |
Coatings for printed circuit board assemblies acc. to EN 61086 |
Yes; Class 2 for high reliability |
Military testing according to MIL-I-46058C, Amendment 7 |
Yes; Discoloration of coating possible during service life |
Protection against fouling acc. to EN 60664-3 |
Yes; Type 1 protection |
Conformal coating |
Qualification and Performance of Electrical Insulating Compound |
Yes; Conformal coating, Class A |
Coolants and lubricants |
Resistant to commercially available coolants and lubricants |
Yes; Incl. diesel and oil droplets in the air |
Decentralized operation |
to SIMATIC S7-1500 |
Yes |
to SIMATIC S7-400 |
Yes |
to standard PROFINET controller |
Yes |
Decentralized operation |
to SIMATIC S7-300 |
Yes |
Decentralized operation |
to SIMATIC S7-1200 |
Yes |
Diagnostics indication LED |
for module diagnostics |
Yes; green/red DIAG LED |
Diagnostics indication LED |
Monitoring of the supply voltage (PWR-LED) |
Yes; green PWR LED |
Diagnostics indication LED |
Receive RxD |
Yes; green LED |
Transmit TxD |
Yes; green LED |
Dimensions |
Depth |
58mm |
Height |
73mm |
Width |
15mm |
Firmware version |
FW update possible |
Yes |
usable BaseUnits |
BU type A0 |
Freeport |
Bits per character |
7 or 8 |
Number of stop bits |
1 or 2 bit |
Parity |
None, even, odd, always 1, always 0, any |
Telegram length, max |
2kbyte; performance mode: receive data max. 24 byte and send data max. 30 byte |
General information |
Product type designation |
CM PtP |
Input current |
Current consumption (rated value) |
31mA |
Current consumption, max |
35mA |
Interface types |
Design of the connection |
Push-in terminal |
Interface types |
RS 232 |
Yes |
Interface types |
RS 422 |
Yes |
Interface types |
RS 485 |
Yes |
Interrupts/diagnostics/status information |
Diagnostics function |
Yes |
Isolation |
Isolation tested with |
750 V DC (type test) and according to EN 50155 (routine test) |
Modbus RTU master |
Address area |
1 to 247, extended 1 to 65535 |
Number of slaves, max |
32 |
MODBUS RTU slave |
Address area |
1 to 247, extended 1 to 65535 |
Other |
Note: |
for use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A, Online Support article 109736776 |
Potential separation |
between backplane bus and interface |
Yes |
Power loss |
Power loss, typ |
0.7W |
Product function |
I&M data |
Yes; I&M0 to I&M3 |
Railway application |
EN 50121-4 |
Yes; EMC for signal and telecommunications systems |
EN 50155 |
Yes; Rail vehicles - temperature class OT4, ST1/ST2, horizontal mounting position |
Railway application |
EN 50125-1 |
Yes; Rail vehicles - see ambient conditions |
EN 50125-3 |
Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track) |
EN 61373 |
Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B |
Railway application |
EN 50121-3-2 |
Yes; EMC for rail vehicles |
EN 50124-1 |
Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC |
EN 50125-2 |
Yes; Stationary electrical equipment - see ambient conditions |
Fire protection acc. to EN 45545-2 |
Yes; For proof of conformity, see Service & Support |
Relative humidity |
With condensation, tested in accordance with IEC 60068-2-38, max |
100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation |
Remark |
Note regarding classification of environmental conditions acc. t |
* The supplied plug covers must remain in place over the unused interfaces during operation! |
RS 232 |
Cable length, max |
15m |
RS 232 auxiliary signals |
RTS, CTS, DTR, DSR, RI, DCD |
Transmission rate, max |
115.2kbit/s |
RS 422 |
4-wire full duplex connection |
Yes |
Transmission rate, max |
115.2kbit/s |
RS 422 |
4-wire multipoint connection |
Yes |
Cable length, max |
1200m |
RS 485 |
Cable length, max |
1200m; 100 to 1200 m, depending on transmission speed |
RS 485 |
Transmission rate, max |
250kbit/s |
Supply voltage |
Reverse polarity protection |
Yes |
Supply voltage |
permissible range, lower limit (DC) |
19.2V |
permissible range, upper limit (DC) |
28.8V |
Rated value (DC) |
24V |
Telegram buffer |
Buffer memory for telegrams |
4kbyte |
Number of telegrams which can be buffered |
255 |
Usage in industrial process technology |
Against chemically active substances acc. to EN 60654-4 |
Yes; Class 3 (excluding trichlorethylene) |
Environmental conditions for process, measuring and control syst |
Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) |
Use in stationary industrial systems |
Against mechanical environmental conditions acc. to EN 60721-3-3 |
Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) |
to biologically active substances according to EN 60721-3-3 |
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
to chemically active substances according to EN 60721-3-3 |
Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
to mechanically active substances according to EN 60721-3-3 |
Yes; Class 3S4 incl. sand, dust, * |
Use on land craft, rail vehicles and special-purpose vehicles |
Against mechanical environmental conditions acc. to EN 60721-3-5 |
Yes; Class 5M2 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) |
against mechanical environmental conditions in agriculture acc. |
Yes; level 1 (Location LE) using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) |
to biologically active substances according to EN 60721-3-5 |
Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request |
to chemically active substances according to EN 60721-3-5 |
Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
to mechanically active substances according to EN 60721-3-5 |
Yes; Class 5S3 incl. sand, dust; * |
Weights |
Weight, approx |
30g |