Предлагаем вам купить "6AG2647-0AH11-1AX1
по выгодной цене оптом или в розницу. Артикул данного товара - "6AG2647-0AH11-1AX1", бренд – "Siemens". Мы осуществляем доставку по Москве и всей России; гарантируем доставку товара в срок. После оформления заказа, наша команда свяжется с Вами для подтверждения заказа и уточнения деталей доставки. Если у Вас возникли вопросы или требуется помощь в выборе товара, Вы можете связаться с нашим отделом продаж.
6AG2647-0AH11-1AX1, 6AG2647 0AH11 1AX1
Acoustics |
Buzzer |
No |
Speaker |
No |
Altitude during operation relating to sea level |
Installation altitude above sea level, max |
2000m |
Altitude during operation relating to sea level |
Ambient air temperature-barometric pressure-altitude |
Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) |
Ambient conditions |
Suited for indoor use |
Yes |
Suited for outdoor use |
No |
Ambient temperature during storage/transportation |
max |
60C |
min |
-25C |
Backlighting |
Backlight dimmable |
No |
Backlighting |
MTBF backlighting (at 25 C) |
50000h |
Clock |
Hardware clock (real-time) |
No |
Clock |
retentive |
No |
Software clock |
Yes |
synchronizable |
Yes |
Complex image objects |
Alarm view |
Yes |
Analog/digital clock |
No |
Bar graphs |
Yes |
f(x) trend view |
No |
Media Player |
No |
Number of complex objects per screen |
5 |
Pointer instruments |
No |
Recipe view |
Yes |
Sliders |
No |
Sm@rtClient view |
No |
Status/control |
No |
System diagnostics view |
No |
Trend view |
Yes |
User view |
Yes |
configuration / header |
Alarm system (incl. buffer and acknowledgment) |
Yes |
Message indicator |
Yes |
Process value default (input) possible |
Yes |
Process value display (output) |
Yes |
Recipe management |
Yes |
Configuration software |
STEP 7 Basic (TIA Portal) |
Yes; via integrated WinCC Basic (TIA Portal) |
STEP 7 Professional (TIA Portal) |
Yes; via integrated WinCC Basic (TIA Portal) |
WinCC Advanced (TIA Portal) |
Yes |
WinCC Basic (TIA Portal) |
Yes |
WinCC Comfort (TIA Portal) |
Yes |
WinCC flexible Advanced |
No |
WinCC flexible Compact |
No |
WinCC flexible Standard |
No |
WinCC Professional (TIA Portal) |
Yes |
Conformal coating |
Qualification and Performance of Electrical Insulating Compound |
Yes; Conformal coating, Class A |
Conformal coating |
Coatings for printed circuit board assemblies acc. to EN 61086 |
Yes; Class 2 for high reliability |
Military testing according to MIL-I-46058C, Amendment 7 |
Yes; Discoloration of coating possible during service life |
Protection against fouling acc. to EN 60664-3 |
Yes; Type 1 protection |
Conformal coating |
Electronic equipment on rolling stock acc. to EN 50155 |
Yes; Class PC2 protective coating acc. to EN 50155:2017 |
Coolants and lubricants |
Resistant to commercially available coolants and lubricants |
Yes; Incl. diesel and oil droplets in the air |
Degree and class of protection |
IP (at the front) |
IP65 |
IP (rear) |
IP20 |
Diagnoses |
Diagnostic information readable |
No |
Dimensions |
Height of housing front |
97mm |
Mounting cutout, height |
82mm |
Mounting cutout, width |
149mm |
Overall depth |
30mm |
Width of the housing front |
165mm |
Display |
Design of display |
FSTN |
Display height |
31mm |
Display width |
87mm |
Number of colors |
4; backlit display only (white, red, green, yellow) |
Screen diagonal |
3.6in |
Emission of radio interference acc. to EN 55 011 |
Limit class A, for use in industrial areas |
Yes |
Emission of radio interference acc. to EN 55 011 |
Limit class B, for use in residential areas |
No |
Enclosure material (front) |
Aluminum |
No |
Plastic |
Yes |
Stainless steel |
No |
Function keys |
Number of function keys |
10 |
Functionality under WinCC (TIA Portal) |
Applications/options |
none |
Functionality under WinCC (TIA Portal) |
Libraries |
Yes |
SIMATIC WinCC Sm@rtServer |
No |
Web browser |
No |
Further protocols |
MODBUS |
Yes; Modicon (MODBUS TCP/IP) |
General information |
Product type designation |
KP300 Basic mono PN |
Image objects |
Buttons |
Yes |
Date/time fields |
Yes |
Geometric objects |
Yes |
Graphic display |
Yes |
Graphic I/O fields (graphics list) |
Yes |
I/O fields |
Yes |
Icons |
Yes |
Number of objects per image |
30 |
Switches |
Yes |
Symbolic I/O fields (text list) |
Yes |
Text fields |
Yes |
Images |
Global image |
Yes |
Image number in the PLC |
Yes |
Image selection by PLC |
Yes |
Number of configurable images |
50 |
Permanent window/default |
Yes |
Industrial Ethernet |
Industrial Ethernet status LED |
2 |
Input current |
Starting current inrush I |
0.5A |
Input current |
Current consumption (rated value) |
0.1A |
Installation type/mounting |
maximum permissible angle of inclination without external ventil |
35 |
Installation type/mounting |
Rack mounting |
No |
Installation type/mounting |
Mounting in landscape format possible |
Yes |
Mounting in portrait format possible |
No |
Mounting position |
vertical |
Wall mounting/direct mounting |
No |
Interfaces |
Number of industrial Ethernet interfaces |
1 |
Isolation |
Isolation tested with |
750 V DC (type test) and according to EN 50155 (routine test) |
Keyboard fonts |
US English |
Yes |
Lists |
Number of entries per graphics list |
30 |
Number of entries per text list |
30 |
Number of graphics lists per project |
100 |
Number of text lists per project |
150 |
Memory |
Flash |
Yes |
Memory available for user data |
1Mbyte |
RAM |
Yes |
Message buffer |
Circulating buffer |
Yes |
maintenance-free |
Yes |
Number of entries |
256 |
retentive |
Yes |
Message system |
Analog messages |
Yes |
Bit messages |
Yes |
Message indicator |
Yes |
Number of alarm classes |
32 |
Number of characters per message |
80 |
Number of process values per message |
8 |
System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... ) |
No |
System messages HMI |
Yes |
Message system |
Number of analog messages |
15 |
Number of bit messages |
200 |
NEMA (front) |
Enclosure Type 4 at the front |
Yes |
Enclosure Type 4x at the front |
Yes |
Number of function keys with LEDs |
alphanumeric keyboard |
Yes; Keyboard |
Keys with LED |
No |
Numeric keyboard |
Yes; Keyboard |
System keys |
Yes |
Number of SD card slots |
With software interfaces |
No |
Online languages |
Number of online/runtime languages |
5 |
Operating systems |
proprietary |
Yes |
Operation (max. tilt angle) |
At maximum tilt angle, max |
40C; = Tmax |
At maximum tilt angle, min |
-25C; = Tmin |
Operation (vertical installation) |
For vertical installation, max |
60C; = Tmax; +70 C for 10 min (OT1, ST1/ST2 acc. to EN 50155) |
For vertical installation, min |
-25C; = Tmin |
Peripherals/Options |
Printer |
No |
SIMATIC HMI MM memory card: Multi Media Card |
No |
SIMATIC HMI SD memory card: Secure Digital memory card |
No |
USB memory |
No |
Power |
Active power input, typ |
3W |
pre-installed operating system |
Windows CE |
No |
Process coupling |
Allen Bradley (DF1) |
No |
Allen Bradley (EtherNet/IP) |
Yes |
LOGO! |
Yes |
Mitsubishi (FX) |
No |
Mitsubishi (MC TCP/IP) |
Yes |
Modicon (Modbus TCP/IP) |
Yes |
Modicon (Modbus) |
No |
OMRON (FINS TCP) |
No |
OMRON (LINK/Multilink) |
No |
S7-1200 |
Yes |
S7-1500 |
Yes |
S7-200 |
Yes |
S7-300/400 |
Yes |
SIMOTION |
No |
SINUMERIK |
No |
WinAC |
Yes |
Processor |
Processor type |
RISC 32 bit |
Project languages |
Languages per project |
32 |
Protocols |
Supports protocol for PROFINET IO |
No |
Protocols |
EtherNet/IP |
Yes |
IRT |
No |
MPI |
No |
PROFINET |
Yes |
Protocols (Ethernet) |
DCP |
Yes |
DHCP |
Yes |
LLDP |
Yes |
SNMP |
Yes |
TCP/IP |
Yes |
Railway application |
EN 50121-4 |
Yes; EMC for signal and telecommunications systems |
EN 50155 |
Yes; rail vehicles - temperature class OT1, ST1/ST2, horizontal at vertical mounting position |
Railway application |
EN 50125-1 |
Yes; Rail vehicles - see ambient conditions |
EN 50125-3 |
Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track) |
EN 61373 |
Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B |
Railway application |
EN 50121-3-2 |
Yes; EMC for rail vehicles |
EN 50124-1 |
Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC |
EN 50125-2 |
Yes; Stationary electrical equipment - see ambient conditions |
Fire protection acc. to EN 45545-2 |
Yes; For proof of conformity, see Service & Support |
Recipe management |
Data records per recipe |
20 |
Entries per data record |
20 |
Number of recipes |
5 |
Recipe memory expandable |
No |
Size of internal recipe memory |
40kbyte |
Relative humidity |
With condensation, tested in accordance with IEC 60068-2-38, max |
100%; RH incl. condensation/frost (no commissioning when condensation present), horizontal at vertical mounting position |
Remark |
Note regarding classification of environmental conditions acc. t |
* The supplied plug covers must remain in place over the unused interfaces during operation! |
Resolution (pixels) |
Horizontal image resolution |
240pixel |
Vertical image resolution |
80pixel |
Security |
Number of user groups |
50 |
Number of user rights |
32 |
Number of users |
50 |
Password export/import |
No |
SIMATIC Logon |
No |
Service tools/configuration aids |
Backup/Restore automatically |
No |
Backup/Restore manually |
Yes |
Device switchover |
Yes |
Simulation |
Yes |
Supply voltage |
permissible range, lower limit (DC) |
19.2V |
permissible range, upper limit (DC) |
28.8V |
Rated value (DC) |
24V |
Supply voltage |
Type of supply voltage |
DC |
Task planner |
Help system |
Yes |
Number of characters per info text |
320 |
task-controlled |
Yes |
time-controlled |
No |
Touch operation |
Design as touch screen |
No; without |
Transfer (upload/download) |
Ethernet |
Yes |
MPI/PROFIBUS DP |
No |
USB |
No |
using external storage medium |
No |
Usage in industrial process technology |
Against chemically active substances acc. to EN 60654-4 |
Yes; Class 3 (excluding trichlorethylene) |
Environmental conditions for process, measuring and control syst |
Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) |
Use in stationary industrial systems |
to biologically active substances according to EN 60721-3-3 |
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
to chemically active substances according to EN 60721-3-3 |
Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
to mechanically active substances according to EN 60721-3-3 |
Yes; Class 3S4 incl. sand, dust, * |
Use on land craft, rail vehicles and special-purpose vehicles |
to biologically active substances according to EN 60721-3-5 |
Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request |
to chemically active substances according to EN 60721-3-5 |
Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
to mechanically active substances according to EN 60721-3-5 |
Yes; Class 5S3 incl. sand, dust; * |
Variables |
Arrays |
Yes |
Limit values |
Yes |
Multiplexing |
Yes |
Number of variables per device |
250 |
Number of variables per screen |
30 |
Structures |
No |
WEB characteristics |
HTML |
No |
HTTP |
No |
Weights |
Weight (with packaging) |
0.38kg |
Weights |
Weight (without packaging) |
0.25kg |